Duplicate Data Plate
Where the data plate is obscured by cabinetry when
the cooker is in the installed position, place a
duplicate data plate on a surface of the cabinetry
adjacent to the cooker.
The manufacturer declines any liability should these
instructions and safety directions not be observed.
Gas Type Conversion
If the hob is to be converted for use with a type of
gas other than that for which it was set in the factory
(indicated on the data plate), the burner injectors
must be replaced as follows:
Remove the pan supports and the burners.
Unscrew the injectors using a 7 mm socket
wrench, and replace them with injectors of
suitable orifice diameter, as indicated on the
appliance data plate.
Reassemble the parts.
If a regulator is required for the new gas type,
instal an approved regulator of appropriate
pressure setting and flow capacity.
Replace the gas type label with one suitable for
the new gas type.
Check the turn down setting of each burner (next
section) and adjust where necessary.
Perform the post installation checks as described
later in this manual.
Adjust turn down setting
Put the tap to the low flame position;
Remove the tap knob and turn the adjusting
screw, situated inside the tap stem using a flat
blade screwdriver (loosening the screw increases
the height of the flame, tightening decreases it).
Note: the adjusting screw must be fully screwed
down for LPG.
Having obtained the low flame setting required
and with the burner lit, abruptly change the
position of the knob several times from minimum
to maximum and vice versa and check that the
flame does not go out.
Post Installation Checks
Perform post installation checks and ensure
proper and safe operation before leaving. Test all
burners individually and in combination.
Leak Check
Ensure all gas control knobs are in the Off
position.
Ensure the gas supply is switched on.
Spray a solution of soapy water onto all gas joints
as well as the full length of any flexible hoses.
UNDER NO CIRCUMSTANCES USE A NAKED
FLAME IN CHECKING FOR LEAKS.
If bubbles appear anywhere, turn the gas supply off,
check all connections and retest.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.
Flame check
Turn each burner on, and ensure that the flame is
blue with minimal yellow tipping. If there is
significant yellow tipping, flame lift off or excessive
noise, check pressure and adjust at the regulator if
necessary.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.
Igniter operation
Check that the igniter for each burner successfully
ignites the gas.
If an igniter fails to work, first remove the plug from
the electrical power outlet, and then check that all
the electrical connections are in place.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.