Installation Instructions
3
LEAK TEST
RECONNECTING GAS
Note:7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
only on the original installation and are not to be reused
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
end of adaptor free of grease, oil and thread sealant.
CAUTION: Use adapters as shown. Connector
nuts must not be connected directly to pipe threads.
WARNING: 1(9(586($123(1
)/$0(727(67)25*$6/($.6
FLARE
NPT
PIPE SIZE
Listed connector ANSI Z21.24
/
CSA 6.10
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
AT LEAST 1/2"
3/8" NPT
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE WRENCHES.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
e
ck all connections for leaks with soapy solution or equivalent.
p
ly soap solution. Leak test solution must not contain ammonia
ch could cause damage to the brass fittings. If leaks are found,
s
e valve, retighten the joint, and repeat the soap test.