Hotpoint EV302X Manuel d'utilisateur Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
9
Electrical Connection
Connecting the supply cord to the electrical mains:
The hob must be connected to a double pole mains switch
which must be installed between the appliance and the
mains. The double pole mains switch must have a minimum
of 3mm of space between the contacts, be sized to the
load and comply with current regulations (the switch must
not be able to disconnect the earth conductor).
The supply cord should conform to BS6004 conductor size
4mm
2
and must be positioned so that no part of it reaches
a temperature of 50°C higher than room temperature.
Before making the connection, make sure that:
the limiter switch (fuse) and the residual wiring can support
the appliance load (see the rating plate, below).
the mains system is properly earthed in compliance with
current regulations and provisions.
there is easy access to the socket or the double pole
mains switch after the appliance is installed.
the isolation switch must not be positioned directly above
the appliance.
IMPORTANT:
If the hob is installed above a built-in oven, the electrical
connection for the hob must be independent of that for the
oven, both for safety reasons and to facilitate the removal of
the oven for maintenance, repair etc.
Electrical Connection
THIS APPLIANCE MUST BE EARTHED.
The installation procedure must be carried out by a qualified
electrician.
The electrical safety of this appliance is guaranteed only if
the appliance is correctly earthed in compliance with the
standards of electrical safety.
The manufacturer can under no circumstances be considered
responsible for any damage that might occur due to incorrect
earthing of the hob.
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12

Commentaires sur ces manuels

Pas de commentaire