Hotpoint 7HPC 640T (AN) R/HA Mode d'emploi Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Rapid (R)
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
100
100
75
55
130
0.70
0.70
0.40
0.40
1.50
3.00
2.60
1.65
1.00
3.30
39
39
28
28
61
86
80
64
50
65x2
218
189
120
73
240
214
186
118
71
236
3.00
2.60
1.65
1.00
3.60
132 (H)
122 (H)
96 (Z)
79 (6)
103x2
286
248
157
95
343
Burner and nozzle specifications
* At 15°C and 1013,25 mbar - dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P. C.S. = 49.47 MJ/Kg
Natural P. C.S. = 37.78 MJ/m³
Table 1 Liquid Gas Natural Gas
Supply pressures
Burner
Diameter
(mm)
Thermal
Power
kW (p.c.s.*)
NominalReduced
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Flow*
g/h
***
**
Flow*
l/h
Thermal
Power
kW (p.c.s.*)
Thermal
Power
kW (p.c.s.*)
Nominal
R
S
S
A
RR
TC
S
A
PC 640 R/HA(OW) RU 7HPC 640T (OW) R/HA
7HPC 640T (AN) R/HA
GB
9
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 23 24