Hotpoint IP 641 S C (IX) UK Mode d'emploi Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
GB
7
Table 1 Liquid Gas Natural Gas
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Rapid (R)
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Mini WOK (MW)
Supply pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
100
75
55
110
3.00
2.60
1.65
1.00
3.50
Nomin. Reduc.
0.70
0.70
0.40
0.40
1.50
By-pass
1/100
(mm)
39
39
28
28
61
Nozzle
1/100
Flow*
g/h
(mm) ***
86
80
64
50
91
Nozzle
1/100
Flow*
l/h
(mm)
286
248
157
95
333
218
189
120
73
254
**
214
186
118
71
250
Burner and nozzle specifications
*
At 15°C and 1013,25 mbar - dry gas
**
Propane P. C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P. C.S. = 37.78 MJ/m
3
116(Y)
110(Y)
96(Z)
79(6)
138
7,30 (531 g/h - G30) (521 g/h - G31)
IP 640 S UK
II2H3+
Gas section
Rated power (kW)Class
Model
Electric section
220-240V~ 50/60Hz
Voltage and frequency
(1)
Power (W)
0,6
The values in g/h refer to the capacities with liquid gas (Butane, Propane).
(1)
IP 641 S C UK
IP 751 S C UK
II2H3+
II2H3+
7,80 (567 g/h - G30) (557 g/h - G31)
10,40 (756 g/h - G30) (743 g/h - G31)
220-240V~ 50/60Hz
220-240V~ 50/60Hz
0,6
0,6
A
S
RS
A
MW
RR
S
S
IP 640 S UK
A
S
SMW
IP 641 S C UK
IP 751 S C UK
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12

Commentaires sur ces manuels

Pas de commentaire