Electrical Connection
WARNING - THIS APPLIANCE MUST BE
EARTHED
The cooker must be connected to the mains power
by a licensed electrician.
The electrical supply for the cooker must be 240 Volt
50 Hz.
1. The fuse and electrical wiring of the home/
premises must support the load of the appliance.
2. The appliance must be earthed.
3. (New Zealand statutory warning): The cooker must
be connected to the electricity supply by a cable
fitted with an appropriately rated plug that is
compatible with the socket-outlet fitted to the final
subcircuit in the fixed wiring that is intended to
supply this cooker.
4. The appliance must be connected to the mains by
means of a double pole switch with a minimum
contact opening of 3 mm. The yellow-green earth
wire must not be interrupted by the switch
5. IMPORTANT If a power socket needs to be
installed or relocated, the work must be done by a
licensed electrician.
Mounting A Power Supply Cable
Open the terminal board by inserting a screwdriver
into the side tabs of the cover. Use the screwdriver
as a lever to open the cover.
Loosen the cable clamp screw and remove it
Remove the wire contact screws L-N- , then fasten
the wires under the screw heads, respecting the
colour code: Black/Blue (N), Red/Brown (L) and Bare
Wire/Yellow-Green.
Once the connections have been made, tighten all
the terminal screws fully.
Fasten the supply cable in place with the clamp and
close the cover of the terminal board.
The supply cable should be positioned so that it is
not subject to direct heat and so that it does not
reach a temperature of more than 50°C higher than
room temperature, along its length. If there is a risk
that the cable will come into contact with parts
having such a temperature rise, then fixed wiring
insulation must be protected using an insulating
sleeve of an appropriate temperature rating.
Before making the connection, check that the home
electrical system can support the appliance load
(see data plate).
NB: Never use reducers, adaptors or shunts since
they can cause heating or burning.
The socket or circuit-breaker must be easily
accessible once the cooker has been installed. The
power cable must not be bent or compressed.
Disconnecting the cable
Ensure that the means for disconnection of the
power cable is incorporated into the fixed wiring in
accordance with local wiring rules.
Sufficient cable should be used to allow the cooker
to be pulled out for servicing.
INSTALLATION & OPERATIONAL
CHECKS
Post Installation Checks
Perform post installation checks and ensure proper
and safe operation before leaving. Test all burners
individually and in combination.
Leak Check
" Ensure all gas control knobs are in the Off
position.
" Ensure the gas supply is switched on.
" Spray a solution of soapy water onto all gas joints
as well as the full length of any flexible hoses.
UNDER NO CIRCUMSTANCES USE A NAKED
FLAME IN CHECKING FOR LEAKS.
If bubbles appear anywhere, turn the gas supply off,
check all connections and retest. If satisfactory
operation cannot be achieved, contact place of
purchase or their appointed agent for service.
Flame check
Turn each burner on, and ensure that the flame is
blue with minimal yellow tipping. If there is
significant yellow tipping, flame lift off or excessive
noise, check pressure and adjust at the regulator if
necessary.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.
Igniter operation
Check that the igniter for each burner successfully
ignites the gas.
If an igniter fails to work, first remove the plug from
the electrical power outlet, and then check that all
the electrical connections are in place.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for