Remote controller
Function description of buttons (P1-04)
1. ON/OFF BUTTON
Starts or Stops the appliance by
pressing this button.
3.FAN BUTTON
Used to select fan speed in sequence
auto, high, medium or low.
4-5.TEMPERATURE BUTTON
Used to select the room
temperature.
Used to set the time in timer mode.
6. SMART BUTTON
Sets or cancels Smart operation.
7. SWING BUTTON
Stops or starts horizontal adjustment
louver swinging and sets the desired
up/down airow direction.
10-11. HUMIDITY BUTTON
Used to set desired humidity level,
they are only available under 6th
SENSE mode.
16. SUPER SILENT BUTTON
Used to start or stop the super
silent operation to have a low noise
environment.
2. MODE BUTTON
Used to select the operation mode.
In sequence Cooling, hearing or fan.
8.SLEEP BUTTON
Used to select the sleep mode in
sequence of sleep 1, sleep 2, sleep 3
sleep 4 and sleep o.
9.AROUND U BUTTON
Used to set or cancel Around U
function.
12.JET BUTTON
Used to start or stop the fast cooling
or heating.
13.DIM BUTTON
Used to turn on or turn o display
light on indoor unit.
14.WI-FI BUTTON
Used to trun on or turn o the Wi-Fi.
15TIMER BUTTON
Used to set the time for turn on or
turn o the appliance.
Symbols on RC display Active RC by pressing UNLOCK button
Cooling indicator Auto fan speed Sleep indicator 1
Press the button, the
backlight will lighted up
and function buttons
will be activated for use.
Press again to lock remote
controller. If no operation
on remote controller
for 10s, the remote
controller will be locked
automatically.
PRESS
Humidity plus indicator High fan speed Sleep indicator 2
Humidity minus indicator Medium fan speed Sleep indicator 3
Fan only indicator Low fan speed Sleep indicator 4
Heating indicator Super silent indicator Display set temperature
Around U indicator Smart Indicator
ON
OF F
Display set timer
Jet indicator Power save indicator Signal transmission
PROTECTION
Operating condition
The protective device maybe trip
and stop the appliance in the cases
listed below.
Heating Outdoor air
temperature is
over 24°C
Outdoor air
temperature is
below -7°C
Room temperature
is over 27°C
Cooling Outdoor air
temperature is
over 43°C
Room temperature
is below 21°C
Dehumidifying Room temperature
is below 18°C
If the air conditioner runs in
COOLING or DRY mode with door
or window opened for a long time
when relative humidity is above
80%, dew may drip down from the
outlet.
Features of protection device
Wait at least 3 minutes before
restarting the unit after operation
stops or changing mode during
operation. After connecting to
power supply and turning on the
appliance immediately, a delay of 20
seconds may occur before it starts to
operate. If all operation has stopped,
press ON/OFF button again to
restart. Timer should be set again if it
has been cancelled.
Features of COOLING mode
Anti-freezing When the temperature
of the indoor heat exchanger drops
to 0° or below, compressor will stop
working to protect the appliance.
Features of HEATING mode
Preheating
In order to prevent cool air blowing,
2-5 minutes are necessary to
preheat the indoor unit at HEATING
operation start. The indoor fan will
not work during preheating.
Defrosting
In HEATING operation the appliance
will defrost (de-ice) automatically
to raise eciency. This procedure
usually lasts 6-10 minutes. During
defrosting, fan stops running and
running indicator ashes.
After defrosting is completeed,
it returns to HEATING mode
automatically.