Installation
WARNING – THIS APPLIANCE MUST BE EARTHED.
Your cooker should have been checked to ensure
that
the voltage corresponds with your supply volt
age,
this is
stated on the rating plate, which is situated
on the front
of the plinth. The cooker must be connected by a com-
petent person eg. (NICEIC registered contractor) to
suitable double-pole control unit with a minimum rating
of 32A and a minimum contact clearance of 3mm,
which should be fitted adjacent to the cooker, in accor-
dance with latest IEE regulations.
The power supply cable should conform to B.S.6004
with a conductor size of 2.5mm
2
minimum.
The control unit should be easily accessible in the
event of an emergency, but must be within 2 metres
of and not directly above an appliance.
This appliance conforms to EN 55014 regarding
suppression of radio and television interference.
Access to the mains terminals is gained by removing
the rear access cover.
The mains cable must pass through the cable clamp
adjacent to the terminal block. Sufficient cable should
be used to allow the cooker to be pulled out for
servicing.
Ensure that the mains cable is routed away from any
brackets affixed to the rear panel and is not trapped to
the rear wall when pushing the cooker into
position between cabinets.