Hotpoint HS MC 07A ZO UK Mode d'emploi Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
99
en
Using the motorized brush
When the product is not in the upright position, the power
suction and the rotating brush are working. To pause the
vacuum cleaner use the start/stop button (32) When the
product is in the park position, the Start&Pause function
switches off the operation of the rotating brush, while the
suction power is on. In this position it is possible to use
the other accessories in the clamp (17).
In cases of using of vacuum cleaner by the handle (E)
This allows you to clean surfaces not accessible with
the motorized brush.
1. Place the suction selector on the accessory
position (27) in the back main body.
2. Fit the two-in-one accessory (24) into the handle
frame, pushing down the handle slide clamp (18).
3. To remove the handle, press the handle release
button (31) and pull it out.
4. Press start/stop button (32) and to start the appliance
press the electronic power regulator (33).
FEATURES
Electronic power regulator
When press this button (33) on the main body the
suction power works cyclically (med -> max -> min
-> med). It allows to set the suction power required.
Ultraviolet light
The UV light (if available) (4) is an ultraviolet steriliza-
tion function, when the brush is collecting dust on the
ground normally, the UV lamp is lighting, antiseptic
function is working. When the brush is not in contact
with an horizontal surface, the UV light is switched off.
To replace the UV light, please contact the nearest
Authorised Service Centre.
Hepa lter
This model comprises the Hepa lter. The Hepa lter
ensures maximum protection against allergens and high
air quality, because the air given back by the appliance
is entirely free from dust/ powder residues.
CLEANING AND MAINTENANCE
Before cleaning or maintaining the vacuum cleaner, make
sure it has been unplugged from the electrical outlet. Do
not use aggressive substances or abrasive materials to
clean the appliance, its internal parts and attachments.
Use a dry or slightly damp soft cloth for cleaning. Make
sure the appliance and all its parts are thoroughly dry
before restarting the appliance. We suggest to clean the
lter at least every 6 months to restore its ltering power.
In any case we recommend replacing the lter at least
every year to ensure maximum performance. Always
operate the vacuum cleaner with the lter installed.
Cleaning the dustbin
For the routine cleaning of the dustbin (G):
1. Press the dustbin release button (6) and take out
the dustbin assembly (7).
2. Keep the dustbin assembly in vertical position
with the lid facing down.
3. Press the lock on the dustbin lid (16) to open the
dustbin container (15).
4. Empty the dustbin.
5. Close the dustbin lid until it clicks into place and
replace it into the main body.
For the washing of dustbin container to remove any
residual dirt (G,H):
1. Before washing the dustbin container, make sure
it has been emptied.
2. Align the screw on the back of the motor cover
(11) with the unblock mark on the dustbin (15) to
open the dustbin, turn the upper dustbin same as
the picture (G).
3. Take out the multicyclonic lter (13).
4. Take out the lower multicyclone (14) from dustbin
container, holding the metal handle same as the
picture (H2).
5. Remove any residual dirt by washing the dustbin
container under running water.
6. Let it dry at room temperature until its parts are
thoroughly dry.
7. Assembly in the reverse order the lower multicy-
clone and the lter.
8. Align the screw on the back of the motor cover
(11) with the blocked mark on the dustbin to
close the dustbin, turn the upper dustbin same
as the picture (G).
9. When the screw on the back of the motor cover
(11) and the blocked mark on the dustbin are lined
up completely, the dustbin is correctly tted.
10. Replace the dustbin assembly into the main
body.
Cleaning the lters (H)
To clean the Hepa lter (10):
1. Open the lter cover (9) using the lever of the
handle on the dustbin same as the picture (H3).
2. Remove the Hepa lter turning it in the direction
indicated on the lter (H4).
3. Wash the lter under running water, taking care
that the jet of water is not too strong.
4. Hold it so that the water ows parallel to its folds.
5. Let it dry at room temperature until all of its parts
are thoroughly dry.
6. Replace the Hepa lter and assembly in the
reverse order.
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Commentaires sur ces manuels

Pas de commentaire