Installation
SPACE FOR FIXING
The cooker can be close fitted below hotplate level.
This requires a minimum distance of 600mm
between cupboard units of hotplate height.
When installing next to a tall cupboard, partition or
wall, for a minimum distance of 400mm above
hotplate level, allow a side clearance of at least
65mm. The diagram below illustrates the minimum
clearance between the cooker and adjacent walls,
cupboards etc.
The wall behind the cooker, 50mm below and
450mm above, and the width of the cooker, must be
a non-combustible material such as ceramic wall
tiles.
If the cooker is to be fitted close to a corner on the
left hand side, ensure that there is a clearance of at
least 50mm to allow the main oven door to open fully
for when removing oven shelves.
65 mm Min
840 mm Min
400 mm Min
600 mm Min
750mm Min
COOKER HOODS
If a cooker hood is to be installed, refer to the
cooker hood manufacturers' instructions regarding
fixing height.
UNPACKING THE COOKER
Unpack the components from inside the grill and
oven.
Check that the following parts are present:
Grill pan and grid Top oven/grill shelf heat shield
Pan supports Main oven shelves (2)
Enamelled burner caps (4) Top oven/grill shelf (1)
Aluminium burner bodies(4) Literature
LOCATION
The cooker may be located in a kitchen, kitchen/
diner or a bed-sitting room, but not in a room
containing a bath or shower. The cooker must not be
installed in a bed-sitting room of less than 20m
3
.
When adjusted for use on Butane (G30) or Propane
(G31), the cooker must not be installed in a room or
internal space below ground level, e.g. in a
basement.
PROVISION FOR VENTILATION
The room containing the cooker should have an air
supply in accordance with BS 5440: Part 2.
The room must have an opening window or
equivalent; some rooms may also require a
permanent vent. If the room has a volume between 5
and 10m
3
, it will require an air vent of 50cm
2
effective area unless it has a door which opens
directly to outside. If the room has a volume of less
than 5m
3
, it will require an air vent of 100cm
2
effective area. If there are other fuel burning
appliances in the same room, BS 5440: Part 2
should be consulted to determine air vent
requirements.
TECHNICAL DATA
Gas connection Rp ½ (½" BSP female)
Pressure test point Front left hotplate injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a
3 pin 13 amp plug
230/240V a.c. 50Hz.
13A fuse.