On completing the operation, replace the old rating label with
the one showing the new type of gas; the sticker is available
from Hotpoint Service (see KEY CONTACTS, back page).
If the gas pressure is different than that prescribed, a pressure
regulator must be installed at the source, in compliance with
national standards governing the use of piped gas regulators.
Regulation of Air Supply to the Burner
The burners do not need a primary air regulator.
Minimum Regulation
Turn the gas valve to minimum.
Remove the knob and turn the regulator screw (positioned
either on the side of the top or inside the shaft) clockwise
until the flame becomes small but regular.
N.B.: In the case of liquid gas, the regulation screw must be fully
screwed in (clockwise).
Make sure that, when the knob is turned rapidly high to low,
the flame does not go out.