TABLE OF CHARACTERISTICS
Dimensions
width 43.5 cm
height 32 cm
depth 40 cm
Volume
56 l
Electrical
connections
voltage: 220-240V ~ 50/60Hz
maximum power absorbed
2800 W
ENERGY LABEL
Directive 2002/40/EC on the
label of electric ovens.
Regulation EN 50304
Declared energy
consumption for Forced
convection Class
heating mode: Gratin
This appliance conforms to
the following European
Economic Community
directives: 2006/95/EEC
dated 12/12/06 (Low
Voltage) and subsequent
amendments - 89/336/EEC
dated 03/05/89
(Electromagnetic
Compatibility) and
subsequent amendments -
93/68/EEC dated 22/07/93
and subsequent
amendments.
2002/96/EEC
Electrical Connection
Electrical connection
The electrical connection to the mains must be made
on the appliance. The power voltage and frequency
are as indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
Using a screwdriver, press on the tabs situated
on each side of the terminal board cover.
Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
_ Unscrew the cable clamp screw and the contact
screws L-N-$.
Fasten the wires beneath the screwheads using
the following colour scheme: Blue (N) Brown (L)
Yellow-Green $
Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical Connection:
Voltage Frequency: 230
V-1+N 50Hz
Fuse Section: 16A
Supply cable:
3x1.5mm
2
You can connect your oven to the system means of
a terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of
its recess in the event of maintenance operations
(only use HAR - H 05 - RRF quality cables fitted with
a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unpl ug t he appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting the appliance
to the flexible
cable, tighten all the screws on the terminal
board.