GB
! The power cord must not be bent or squashed.
! The power cord is supplied fitted with a BS1363 plug and with
a 13 amp BS1362 fuse. If it is necessary to fit a replacement
fuse, it must be a 13 Amp ASTA approved to BS1362 type.
WARNING: The plug must not be used without a fuse cover.
If a replacement fuse holder/cover is required, it must be of the same
colour coding or wording as shown on the base of the plug.
Replacements are available from authorised dealers.
Changing the plug
The wires in the power cord are coloured in accordance with
the following.
! If the plug being replaced is a non-rewirable type, then the
cut-off plug must be disposed of safely. DO NOT leave it where
it can be inserted into a socket and create a shock hazard.
! The power cord should be checked periodically and replaced
by a cord specially prepared for this dryer and fitted only by
authorized technicians (see Service). New or longer power
cords are supplied at an extra charge by authorized dealers.
! The manufacturer denies any responsibility should any of these
rules not be followed.
! If in doubt about any of the above consult a qualified
electrician.
Levelling the tumble dryer
The dryer must be installed level for correct operation.
When you have installed your dryer in its final location check
that it is level first side-to-side, then front to back. If the dryer is
not level, adjust the two legs up or down until your dryer is level.
Before you start using your dryer
Once you’ve installed your dryer and before you use it, clean
the inside of the drum to remove any dust that could have
accumulated during transportation.
Warning ! Before you use your dryer ensure that its has
been in a upright position for at least 6 hours.
Where to put your dryer
Place your dryer at a distance
from gas ranges, stoves, heaters,
or cooktops because flames can
damage the appliance. If you
are going to install the appliance
under a work counter, be sure to
leave a 10 mm space between
the top and any other objects on
or above the machine and a 15
mm space between the sides and
lateral furnishings or walls. This is
to ensure proper air circulation.
Ventilation
• When the dryer is in use, there has to be adequate ventilation.
Make sure you put your dryer in an environment that is not damp
and has proper air circulation throughout. Airflow around the dryer is
essential to condense the water produced during the washing, the
dryer will not operate efficiently in an enclosed space or cupboard.
! If using the dryer in a small or cold room some
condensation will be experienced.
! We do not recommend that the dryer is installed in a
cupboard but the dryer must never be installed behind a
lockable door, a sliding door or a door with a hinge on the
opposite side to that of the dryer door.
Water Drain
If the machine is positioned close to a drain it is possible to drain
the condensed water directly without using the waterbottle. In
which case it is no longer necessary to empty the water bottle at
the end of each cycle. If the Dryer is positioned above or close to
a Washing Machine the same drainage can be used. Just unlink
the tube indicated in figure A and connect it to the drainage.
If the drainage is further away than the length of the tube it is
possible to buy and connect a tube of the same diameter and
the necessary length in order to reach the drainage. To install the
new tube just substitute the existing one as indicated in figure B
inserting it in the same place.
! The drain tube has to be below 1 m from the bottom of the Dryer.
! Once the Dryer has been installed please assure that the drain
tube is not bent or contorted.
Electrical connection
Make sure of the following before you insert the plug into the
electrical socket:
• Ensure your Hands are dry.
• The socket must be grounded.
The socket must be able to sustain the machines maximum power,
which is indicated on the rating label (see Dryer Description).
• Power voltage must be within the values indicated on the
rating label (see Dryer Description).
• The socket must be compatible with the dryers plug.
Should this not be the case, replace the plug or the socket.
! Do not use extension cords.
! The dryer must not be installed outdoors, even if the space is
sheltered. It can be very dangerous if exposed to rain or storms.
! Once installed, the dryers electrical wire and plug must be within reach.
Installation
10 mm
15 mm
15 mm
Moulded plug
GREEN &
YELLOW
BROWN
BLUE
13 ampere fuse
CROSS-BAR
CORD GRIP
Green and Yellow (Earth)
wire to terminal marked “E”,
symbol x, or coloured green
and yellow.
Blue (Neutral) wire to
terminal marked ”N” or
coloured black.
13A ASTA approved fuse to
BS 1362.
Brown (live) wire to teminal
marked “L” or coloured red.
2
H<1m
2
Fig. A Fig. B
Vue de la page 3