4
Use
The hood is designed to be used either for exhausting or filter
version.
Ducting version
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe 13A not supplied).
Filter version
If cooking fumes and vapours cannot be externally discharged
even if using the model with chimney flue C, the cooker hood
can be used in the recirculating version F: the installation of
two active carbon filters E allows the recirculation of fumes
and vapours through the upper grid G.
According to the specific model the recirculating grids can be
already stamped on the flue or must be mounted on the two
lateral sides of the flue (16F).
If the flue is pre-stamped the two parts O extensions must be
placed on the deflector 13F.
Warning! Part O not required with models that are supplied
with 2 specially designed plastic recirculating grills - Parts
16F.
Installation
The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the
range hood must be not less than 60cm from electric cookers
and 70cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Warning! Power cable replacement must be undertaken by
the authorised service assistance centre or similar qualified
person.
Mounting
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.