WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 in.
(107 cm) of your washer’s water inlet. The faucets MUST
EH  LQ  FP JDUGHQ KRVHW\SH VR LQOHW KRVHV FDQ
be connected. Water pressure MUST be between 10 and
120 pounds per square inch. Your water department can
advise you of your water pressure.
NOTE: A water softener is recommended to reduce buildup
of scale inside the steam generator if the home water
supply is very hard.
12
CONNECTING INLET HOSES (on some
models)
To produce steam, the dryer must connect to the cold
water supply. Since the washer must also connect to the
cold water, a “Y” connector is inserted to allow both inlet
hoses to make that connection at the same time.
NOTE: Use the new inlet hoses provided; never use old
hoses.
1. 7XUQWKHFROGZDWHUIDXFHWRȺ5HPRYHWKHZDVKHULQOHW
KRVHIURPWKHZDVKHU¿OOYDOYHFRQQHFWRUFROG
2. (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGVFUHZWKH
IHPDOHFRXSOLQJRIWKH VKRUWKRVHRQWRWKHZDVKHU¿OO
YDOYHFRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
3. Attach the female end of the ‘’Y’’ connector to the male
FRXSOLQJRIWKHVKRUWKRVH(QVXUHWKHUXEEHUÀDWZDVKHU
LVLQSODFH7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
4. ,QVHUW WKH ¿OWHU VFUHHQLQWKHFRXSOLQJRIWKHZDVKHU·V
LQOHW KRVH ,I D UXEEHU ÀDW ZDVKHU LV DOUHDG\ LQ SODFH
UHPRYHLWEHIRUHLQVWDOOLQJWKH¿OWHUVFUHHQ$WWDFKWKLV
coupling to one male end of the ‘’Y’’ connector. Tighten
E\KDQGXQWLO¿UPO\VHDWHG
5. (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFKWKH
dryer’s long inlet hose to the other male end of the ‘’Y’
FRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
6. (QVXUH WKH UXEEHU ÀDW ZDVKHU LV LQ SODFH DQG DWWDFK
WKH RWKHU HQG RI WKH GU\HU·V ORQJ LQOHW KRVH WR WKH ¿OO
valve connector at the bottom of the dryer back panel.
7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
12
CONNECTING INLET HOSES (cont.)
7. Using pliers, tighten all the couplings with an additional
two–thirds turn.
NOTE: Do not overtighten. Damage to the couplings may
result.
8. Turn the water faucet on.
9. Check for leaks around the ‘’Y’’ connector, faucet and
hose couplings.
13
SERVICING
WARNING - LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICING/INSTALLATION.
For servicing phone numbers for replacement parts, and
other information, refer to Owner’s Manual or visit our
Web site.
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
Please go to www.GEAppliances.com or mail in your
3URGXFW5HJLVWUDWLRQ&DUG
For questions on installation, call: 800.626.2000 (US) or
&DQDGD
Vue de la page 7
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire