10
WHAT YOU WILL NEED
Copper or GE SmartConnect
Refrigerator Tubing kit,
1/4” outer diameter to connect the refrigerator to the
water supply. If using copper, be sure both ends of the
tubing are cut square.
To determine how much tubing you need: measure the
distance from the water valve on the back of the
refrigerator to the water supply pipe. Then add 8’
(2.4 m). Be sure there is sufficient extra tubing
(about 8’ [2.4 m] coiled into 3 turns of about 10”
[25 cm] diameter) to allow the refrigerator to move out
from the wall after installation.
INSTALLING THE WATER LINE (ON SOME MODELS)
Installation Instructions
BEFORE YOU BEGIN
Recommended copper water supply kits are WX8X2,
WX8X3 or WX8X4, depending on the amount of tubing
you need. Approved plastic water supply lines are GE
SmartConnect
Refrigerator Tubing (WX08X10006,
WX08X10015 and WX08X10025).
When connecting your refrigerator to a GE Reverse
Osmosis Water System, the only approved installation is
with a GE RVKit. For other reverse osmosis water
systems, follow the manufacturer’s recommendations.
This water line installation is not warranted by the
refrigerator or icemaker manufacturer. Follow these
instructions carefully to minimize the risk of expensive
water damage.
Water hammer (water banging in the pipes) in house
plumbing can cause damage to refrigerator parts and
lead to water leakage or flooding. Call a qualified
plumber to correct water hammer before installing
the water supply line to the refrigerator.
To prevent burns and product damage, do not hook up
the water line to the hot water line.
If you use your refrigerator before connecting the water
line, make sure the switch is set to OFF or the feeler arm
in the STOP (up) position.
Do not install the icemaker tubing in areas whe re
temperatures fall below freezing.
When using any electrical device (such as a power drill)
during installation, be sure the device is double insulated
or grounded in a manner to prevent the hazard of
electric shock, or is battery powered.
All installations must be in accordance with local
plumbing code requirements.
1
WHAT YOU WILL NEED (CONT.)
GE SmartConnect
Refrigerator Tubing Kits are available
in the following lengths:
6’ (1.8 m) – WX08X10006
15’ (4.6 m) – WX08X10015
25’ (7.6 m) – WX08X10025
Be sure that the kit you select allows at least 8’ (2.4 m) as
described above.
NOTE: The only GE approved plastic tubing is that
supplied in GE SmartConnect
Refrigerator Tubing
kits. Do not use any other plastic water supply line
because the line is under pressure at all times. Certain
types of plastic will crack or rupture with age and
cause water damage to your home.
A GE water supply kit (containing tubing, shutoff valve
and fittings listed below) is available at extra cost from
your dealer or from Parts and Accessories,
1.800.661.1616.
A cold water supply. The water pressure must be
between 20 and 120 p.s.i. (1.4–8.1 bar).
Power drill.
1/2 or adjustable wrench.
Straight and Phillips
blade screwdriver.
Two 1/4 outer diameter compression nuts and
2 ferrules (sleeves)—to connect
the copper tubing to the shutoff
valve and the refrigerator water valve.
OR
• If you are using a GE SmartConnect
Refrigerator
Tubing kit, the necessary fittings are preassembled
to the tubing.
• If your existing copper water line has a flared fitting at
the end, you will need an adapter (available at
plumbing supply stores) to connect the water line to
the refrigerator OR you can cut off the flared fitting
with a tube cutter and then use a compression fitting.
Do not cut formed end from GE SmartConnect
Refrigerator tubing.
Shutoff valve to connect to the cold water line.
The shutoff valve should have a water inlet with a
minimum inside diameter of 5/32” at the point of
connection to the COLD WATER LINE. Saddle-type
shutoff valves are included in many water supply kits.
Before purchasing, make sure a saddle-type valve
complies with your local plumbing codes.