PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Gas connection
The cooker should be connected to the gas-supply by a Gas Safe registered installer. During installation of
this product it is essential to fit an approved gas tap to isolate the supply from the appliance for the convenience
of any subsequent removal or servicing. Connection of the appliance to the gas mains must be carried out
according to the prescribed regulation in force, and only after it is ascertained that
it is adaptable to the type
of gas to be used.On some models the gas supply can be connected on the left or on the right, as necessary;
to change the connection, reverse the position of the hose holder with that of the cap and replace the gasket
(supplied with the appliance). In the case of connection to liquid gas, by tank, use pressure regulators that
conform to the regulation in f
orce. The gas supply must be connected to the left of the appliance. Be sure that
the hose does not pass through the rear of the cooker touching hot parts.
HOT PARTS
600 mm
Important: make sure the supply pressure conforms with the values shown in the table entitledCaracteristics of
the burners and nozzles”. When the cooker is installed between cabinets (recessed), the g
as connection
must be effected by an approved flexible hose with bayonet fitting (BS 669 Current Edition). The gas inlet
for the cookers is a threaded G 1/2 gas female fitting.
Connecting the gas supply
To make the connection, a flexi
ble hose should be used corresponding to the current gas regulations which are:
the hose must never be at any point in its lenght in contact with the “hot” parts of the cooker;
the hose must never be longer than 1,5 metre;
the hose must not be subject to any tension or torsional stress and it must not have any excessively narrow
curves or bottlenecks;
the hose must be easy to
inspect along its entire length to check its condition;
the hose must always be in good condition, never attempt to repair.
Important: the installation must comply with gas safety (installation and use) regulations 1984. In all cases for the
above, by low, a qualified,Gas Safe approved engineer must be called for installation.
Disposing of the appliance
When disposing of the appliance please remove the plug
by cutting the mains cable as close as possible to the
plug body and dispose of it as described above.
turn the tap to minimum;
remove the knob and adjust the regulation screw, which is positioned in or next to the tap pin, until the
flame is small but steady.
N.B.: in the case of liquid gas,
the regulation screw must be screwed in to the bottom.
check that the flame does not turn off when you turn the tap quickly from high to low.