Electrical Connection - Model E6002
Electrical Connection
THIS APPLIANCE MUST BE EARTHED.
The installation procedure must be carried out by a qualified
electrician.
The electrical safety of this appliance is guaranteed only
if the appliance is correctly earthed in compliance with the
standards of electrical safety.
The manufacturer can under no circumstances be
considered responsible for any damage that might occur
due to incorrect earthing of the hob.
IMPORTANT POINTS:
Your hob is supplied with a special connection cable.
If ever the cable is damaged it should be replaced by an
authorised service engineer only.
Disconnect the hob form the electrical supply before any
work is carried out.
Voltage and frequency of power supply:
230-240V
50-60Hz
6500W
Electrical Connections:
To connect the supply cord, proceed as follows:
- Loosen the screws on the wire clamp "V", as well as the
screws for the contacts.
- Insert the wires beneath the contact screws, as shown in
the diagram and tighten them.
- Fasten the cord with the appropriate wire clamp and close
the cover.
* Application of the simultaneity coefficient in compliance
with standard EN 335-2-6
Y-type connection in compliance with standard
EN 335-2-6
Connecting the supply cord to the electrical mains:
The hob must be connected to a double pole mains switch
which must be installed between the appliance and the
mains.. The double pole mains switch must have a minimum
of 3mm of space between the contacts, be sized to the
load and comply with current regulations (the switch must
not be able to disconnect the earth conductor).
The supply cord should conform to BS6004 conductor size
4mm
2
and must be positioned so that no part of it reaches
a temperature of 50°C higher than room temperature.
Before making the connection, make sure that:
the limiter switch and the residual wiring can support
the appliance load (see the rating plate).
the mains system is properly earthed in compliance
with current regulations and provisions.
there is easy access to the socket or the double pole
mains switch after the appliance is installed.
IMPORTANT:
If the hob is installed above a built-in oven, the electrical
connection for the hob must be independent of that for the
oven, both for safety reasons and to facilitate the removal
of the oven for maintenance, repair etc.
LN
Fuse 20 A*
Vue de la page 11