Hotpoint SY23 Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 21
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
INSTALLATION
Installation location
In order for the gas unit to work properly it is essential that the air necessary for burning
the gas flows into the area naturally.
The installer must follow the safety norms for the country of installation.
The flow of air into the area must come directly through openings made in the exterior
walls.
These openings must have a free passage section of at least 100 cm² (one or more
openings can be made).
Products of combustion must be exhausted through a hood connected to a fume flue
or directly outside.
In the event that it is not possible to install the hood, it is necessary to use an electric
ventilation fan installed in the outside wall or window of the area so long as there is
an opening for air to enter the area in conformity with current law.
This electric ventilation fan must have a flow capacity sufficient to guarantee that
3 to 5 times the volume of air in the room is exchanged every hour.
ELECTRICAL CONNECTION
Attention: do not connect to the power supply before you have finished connecting
the oven and cooktop.
Make sure that installation and hook-up are performed by a qualified technician
in accordance with the manufacturer's instructions and in compliance with local
regulations. The installer is responsible for the correct electrical connection and for
the observance of the safety rules.
The oven must be connected to the electricity supply by means of an all-pole disconnect
switch with minimum contact gap of 3 mm.
The appliance must be earthed by law.
Do not use multiple sockets or extensions.
After the oven has been installed, the electrical components must be inaccessible.
Make sure that the voltage stated on the appliance rating plate is the same as the
voltage in your home. The rating plate is on the lower front edge of the oven (visible
with the door open).
If the power supply cable needs replacing, make sure that it is replaced with a cable
similar to the one provided by the Manufacturer (H05 RR-F type) and that installation
is performed by the Service Center or a qualified technician.
The appliance is equipped with the cable for the electrical connection without plug.
GB
6
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 20 21

Commentaires sur ces manuels

Pas de commentaire