18
•
For ovens installed under the worktop, leave a minimum clearance of 5 mm between the upper edge
of the oven and the lower edge of the worktop (fig. 5).
For correct operation of the appliance, this
clearance must always be unobstructed.
•
If the kitchen unit is not securely fixed to the wall, it must be anchored with standard brackets
(A)
(fig. 6).
Electrical connection
Regulations require that the appliance be earthed.
•
Connection to the mains must be carried out by a qualified technician in accordance with the
manufacturer's instructions and in compliance with local regulations.
•
The installer is responsible for connecting appliances correctly to the mains and for observing the safety
regulations.
•
The oven power cable must be long enough to connect the built-in oven to the mains.
•
Observance of safety directives requires that a multi-pole switch with a minimum contact gap of 3 mm
be used for the installation.
•
Do not use multiple plug adapters or extension leads.
•
After the oven has been installed, the electrical components must be inaccessible.
5
6