Hotpoint C60ETC Mode d'emploi Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
4
INSTALLATION
WARNING - THIS APPLIANCE MUST BE EARTHED.
Mains Connection
Your cooker should have been checked to ensure that the voltage corresponds with your supply voltage, this is
stated on the rating plate, which is situated on the outer rear panel.
The model number and serial number are located on the front of the cooker, as shown on the Feature's page.
The cooker must be connected by a competent person such as one who is a, NICEIC registered contractor to a
suitable double-pole control unit with a minimum rating of 32A and a minimum contact clearance of 3mm
(applicable to newer properties, older properties where a 30A double pole control unit and a minimum contact
clearance of 3mm is acceptable).
The double pole control unit should be fitted adjacent to the cooker, in accordance with IEE regulations. The
control unit must be within 2 metres of but not directly above the appliance and should be easily accessible in
the event of an emergency.
The power supply cable should conform to B.S.6004 with a conductor size of 6mm2, minimum.
Access to the mains terminals is gained by removing the rear access cover. The mains cable must pass
through the cable clamp adjacent to the terminal block. Sufficient cable should be used to allow the cooker to
be pulled out for servicing.
Ensure that the mains cable is routed away from any brackets affixed to the rear panel and is not
trapped to the rear wall when pushing the cooker into position between cabinets.
Levelling
Four feet are fitted which can be adjusted up or down to set the height (900mm - 930mm) and level the cooker.
The feet can be simply screwed in or out to lower or raise the cooker.
After the correct height is achieved, lock the feet into position by tightening the locking nut using an open
ended spanner.
CAUTION:CAUTION:
CAUTION:CAUTION:
CAUTION: Some soft floor coverings may get damaged if the cooker is not moved carefully.
NOTE:NOTE:
NOTE:NOTE:
NOTE: Ensure oven shelves are level by using a spirit level on the rod shelves.
Siting the Cooker
The cooker is designed to fit between kitchen cabinets spaced 600mm apart. The space either side need only
be sufficient to allow withdrawal of the cooker for servicing and cleaning.
It can be used with cabinets one side or both as well as in an angled corner setting. It can also be used
freestanding.
Adjacent side walls which project above hob level, must not be nearer to the cooker than 150mm and should be
protected by heat resistant material. Any overhanging surface or cooker hood should not be nearer than 650mm.
Note: This appliance must NOT be fitted on a platform.
Moving the Cooker
Before moving your cooker, switch off at the cooker control unit, ensure that it is cool.
Open the grill door sufficiently to allow a comfortable grip on the underside front edge of the oven roof, avoiding
any grill elements.
Radio Interference
This appliance conforms to EN 55014 regarding suppression of radio and television interference.
Note: Take care in moving the cooker as it is heavy. Take care to ensure that any floor covering is not
damaged.
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 35 36

Commentaires sur ces manuels

Pas de commentaire