Hotpoint ACM 353 WH Mode d'emploi Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
N C
M Y
INSTALLATION
Gas connection with pipe fitting
The fitting assembly (Fig. 6) consists of a fitting “B” for G 30/G 31,
a fitting “C” for G 20 and a gasket “D”.
Natural gas G 20
The connection is by a flexible pipe, a gas fitting “C” and a gasket
“D” (Fig. 6).
Thepipemusthaveaninternaldiameterof15mm,andbe
sufficiently tightened to be kept in place by the pipe clamp (not
supplied). This pipe must be replaced before its expiry date.
Liquid Gas G 30/G 31
Connection is by fitting “B” and gasket “D” withaflexiblepipe
with 6 mm internal diameter, and suitable for gas supply from a gas
cylinder or tank (Fig. 6).
IMPORTANT!
Always replace the pipe before its expiry date.
Use two spanners to remove the fitting (Fig. 7).
When tightening, use a normal torque value not exceeding 2.5
N/m (Kgf/m) as a precautionary measure.
Keep the rubber pipe as short as possible, with no loops or
twists.
After connection, check the coupling tightness with a soapy
solution, but never with a naked flame.
Fig. 6
Fig. 7
D
B
C
Cat.II
2H3+
G 30/G 31 G 20
28-30/37 mbar 20 mbar
By-pass Ø nozzle Ring opening By-pass Ø nozzle Ring opening
(1/100) mm (1/100 mm) (mm) (1/100) mm (1/100 mm) (mm)
Burners
Thermal
Reduced
load
thermal
(KW)
load
(KW)
Auxiliary (A) 1.00 0.30 27 50 3* adjustable 72 1*
Medium-speed (SR) 1.90 0.38 29 67 5,7* adjustable 100 2*
High speed (R) 3.15 0.60 39 86 all open* adjustable 130 5*
* = reference value
x
All operations for changing the cooker from natural gas to butane or propane or vice versa must
only be carried out by a qualified service engineer.